Search for Products
The Problem
Excessive fats, oils and grease (FOG) in lagoons, grease traps and sumps. Decom-
position of matter by naturally occurring bacteria and/or chemical reactions will release
gases (H2S) to the atmosphere that have a very offensive smell. Our Biodigesters (O)
is the answer to control of odors in wastewater.

Target The Problem
Remove the food source for naturally occurring bacteria. Biodigesters (O) product quickly
eliminates fats, oils, grease and hydrocarbons in wastewater and out competing the natural
occurring bacteria.

Biodigesters (affectionately referred to as “bugs”) are a combination of all natural bacteria,
lab grade purified enzymes with micro and macronutrients.  Biodigester O bacteria and
enzymes are targeted to the food sources available. By out competing the natural occurring
bacteria for the food sources, odor causing bacteria die off and thus the objectionable smell
is eliminated.

Biodigesters are so prolific they multiply by double every 15-20 minutes. If you start out with
one cell in fifteen minutes you have two and so on. In 8 hours you will have 17-million and in
twenty-four hours you have a 1 with one hundred and twenty six zeros behind it. They simply
out number the bacteria present in the system.

The Selection Process
There are over 3,000 known bacterial strains. Our bacteria and enzymes are selected for their
ability to aggressively breakdown the targeted substrate. First, we select only facultative strains
that can operate aerobic (with oxygen) or anaerobic (oxygen depleted) situations. Our bacteria
are most effective in an aerobic state working 5-7 times faster. We also take into consideration
other factors like resistance to; high and low pH, chemical shock and temperature. HBD can tol-
erate a Ph of 4.5 to 9.5 without dieing off, but…the closer to neutral pH of 7 the better. They are
resistant to disinfectants like chlorine up to 150 PPM and remain active in temperature ranges of
50-140 degrees F.

Safe To Use
All Biodigester products are guaranteed pathogen free; every batch is checked for purity. Our
bacterial strains are Not Genetically Engineered , they are all naturally occurring strains.

Dry And Liquid Formulas
Biodigester (O) is supplied in two forms, liquid and dry. The patented process used to microen-
capsulate our product protects it from activation in its dry form. We guaranty an active cell count
of 2.7 trillion cells per lb. for two years. Once stabilized in a liquid that does not break the micro
encapsulation process. Biodigester (O) remains 100% viable with a cell count of 450 billion per
gallon for one full year.

Dosing Rates
HBD Dry formula is used for seed dosing (initial propagation) at a rate of one pound per 2,000
gallons of wastewater. You simply mix the product into warm (not hot) water and evenly intro-
duce it into all water holding tanks within the system.

Biodigester Liquid can be automatically dosed into the water holding body with our unique Ultra
Dose system. For every one minute of run time the auto-doser adds 3 oz. to the system. Appli-
cation rates are 3 oz. per 1,000 gallons of water per day. In a 6,000 gallon system you will
dose six times evenly spaced through out a 24 hour period (every four hours) seven days per
week. Liquid HBD can be purchased in 6, 15, 30 and 55-gallon drums.

How They Work
Biodigesters enzymes and microorganisms work in concert to digest long chain hydrocarbons,
light fuels, sludge, fats, and grease. Biodigester targeted enzymes breakdown the substrate for
digestion by the bacteria. In high hydrocarbon applications nutrients supplement the bacteria’s
diet. The result is a significant reduction of BOD/COD and TSS. The byproducts produced from
this biological transformation are absolutely harmless and “stink” free – only carbon dioxide and
water remain.

They propagate the bottom solids reducing them and liberating oils and grease into the water
column for digestion. Floating fatty crust is broken down and eliminated. Our bacteria take up
residence in the entire system constantly eating it clean, coalescing plates are kept clean, pipes
and valves don’t plug up.

Proven Applications
Biodigesters can be used just about everywhere that (FOG) problems exist. This includes:
Septic Tanks, Animal Process Waste Lagoons, Settling Tanks, In-Ground Separators, Oil
Coalescing Systems, Grease Traps, Above Ground Separators, Waste Holding Tanks,
Evaporation Ponds.

Contact us for the safe, economical, and productive solution to wastewater management.  
Biodigesters are the answer.
...HBD-O / Oil Treatment Formula
HYDRO-BIODIGESTER
FLORIDA WATER BLAST, INC.  Clearwater Florida Ph. 1-727-789-5786

Bett Conveyor (2) Picture
HYDRO MAIN STEEL Pad
Hydro Biodigester 101
Biodigesters How To?
Biodigesters Oil
Biodigesters MAIN
Biodigesters C  Algae
Biodigester Products
Landa Bio Puck HC Brochure 2 Pgs..pdf
CONSTRUCTION